Splunk Integration streams NetBeez alert, Scheduled Test Alert, aggregate alert, and Incident events directly to a Splunk Enterprise or Splunk Cloud HTTP Event Collector (HEC) endpoint (/services/collector) as structured JSON events.
In this article:
Step 1: Create an HTTP Event Collector (HEC) Token in Splunk
Sign in to Splunk Enterprise or Splunk Cloud as an administrator and navigate to Settings → Data Inputs → HTTP Event Collector.
Click Global Settings and verify that All Tokens is set to Enabled (note your HEC port—commonly
8088on Splunk Enterprise or443on Splunk Cloud—and whether Enable SSL is checked).Click New Token, enter a descriptive Name (for example,
NetBeez NextGen), leave Enable indexer acknowledgment unchecked unless your HEC receiver proxy handles acknowledgments, select your target Splunk index(es), and complete the wizard.Copy the generated Token Value.
Step 2: Configure & Test Splunk in NetBeez Settings
Users with the Administrator role configure Splunk under Settings:
Click Settings in the left navigation sidebar, expand Integrations & Notifications, and select Splunk (
/settings/integrations/splunk).Complete the Splunk Configuration fields:
Endpoint URL (required) — Full URL to your Splunk HEC collector endpoint ending in
/services/collector(for example,https://splunk.example.com:8088/services/collectororhttps://http-inputs-<stack>.splunkcloud.com:443/services/collector).HEC Token (required on initial setup) — Paste the Splunk HEC token value. NetBeez sends this value in the
Authorization: Splunk <hec_token>HTTP header and stores it encrypted. Once saved, you can leave HEC Token blank when updating other fields unless rotating the token.SSL Verification — Checked by default to validate your Splunk HEC server's TLS certificate. Uncheck only if your on-premises Splunk HEC listener uses a self-signed certificate.
Click Test to send a live HEC test event (
{"event":"Test message from NetBeez Splunk integration"}) using your current form values before saving. Confirm the Splunk Test Succeeded toast banner appears and verify the event in Splunk Search.Click Apply Changes to save the configuration.
Step 3: Select Alert & Incident Notification Events
In the Notifications card, switch the top-right toggle to Enabled.
Toggle the desired event types across the four columns and click Save:
Agents — Device Alerts (Agent Device Alerts), Aggregate Alerts, and Incidents (Agent Incidents).
Targets — Alerts (Target Alerts), Aggregate Alerts, and Incidents.
Wi-Fi Profiles — Alerts, Aggregate Alerts, and Incidents.
Scheduled Tests — Alerts (Scheduled Test Alerts) and Aggregate Alerts.
Splunk HEC JSON Event Structure
NetBeez posts each notification to /services/collector with a 5-second open timeout and 10-second read timeout (suppressed automatically during Maintenance Mode). Every HEC envelope includes sourcetype: "_json", host (your NetBeez dashboard URL), time (epoch seconds), and event containing the full JSON:API resource payload (identical to the Webhook Integrationdata object):
{
"time": 1763906400,
"host": "https://netbeez.example.com",
"sourcetype": "_json",
"event": {
"data": {
"id": "4e1c2b3a-8d9f-4123-9abc-0123456789ab",
"type": "alert",
"attributes": {
"severity": 1,
"severity_name": "alert",
"alert_dedup_id": "4e1c2b3a-8d9f-4123-9abc-0123456789ab",
"event_type": "ALERT_OPEN",
"agent": "Pittsburgh HQ",
"target": "Corporate DNS",
"destination": "10.10.1.53",
"message": "5 consecutive DNS checks failed",
"test_type": "DnsTest",
"alert_ts": 1763906400000
}
}
}
}Aggregate Alerts: When Aggregate Alerts is enabled, NetBeez sends one HEC JSON payload per alert in the batch, including
aggregation_entity_type("agent","target","wifi_profile", or"scheduled_test") andtest_countsinsideevent.data.attributes.Incidents: Incident payloads set
event.data.typeto"incident"withevent("INCIDENT_OPEN"or"INCIDENT_CLEARED"),incident_id, entity name/UUID, dashboardurl,event_ts, andincident_ts.