SNMP Trap MIB & Payload Reference

Download the NETBEEZ-BEEZKEEPER-MIB v4.0 file and reference SNMPv1 and SNMPv2c trap OIDs, UUID varbinds, and UTC DateAndTime encodings in NextGen.

Written by Panickos Neophytou

When SNMP Integration is enabled in NetBeez NextGen (Version 20.0+), your NetBeez server forwards SNMPv1 or SNMPv2c traps to your network management system (NMS) using NETBEEZ-BEEZKEEPER-MIB (Version 4.0). Load the MIB into your trap receiver so numeric OIDs, UUID strings, and UTC timestamps decode into human-readable fields.

In this article:

Downloading the NetBeez MIB (v4.0)

Download the official MIB module from the NetBeez GitHub repository (or click Download NetBeez MIB directly inside Settings → Integrations & Notifications → SNMP):

Upgrading from Legacy 15.x (MIB v3.3): Replace NETBEEZ-BEEZKEEPER-MIB-v3.3.my on your NMS with Version 4.0. In NextGen 20.0, all alert, agent, incident, and source-object identifiers are UUID strings (OCTET STRING), timestamps use 11-octet UTC DateAndTime, incidentEventNotification resides under nbAlertNotifications (.1.0.3), and testType adds Scheduled Test and Path Analysis enumerations.

Enterprise OID & SNMPv1 vs. SNMPv2c Trap Mapping

All NetBeez trap definitions live under the NetBeez Private Enterprise Number (44523) at beezKeeperMIB (1.3.6.1.4.1.44523.1):

Notification Category

MIB Notification Name

SNMPv1 Specific Trap

SNMPv2c Trap OID

Agent Device Alert

beezAlertNotification

enterpriseSpecific (6) / 1

1.3.6.1.4.1.44523.1.0.1

Target, Wi-Fi, Scheduled Test & Verification Alert

testAlertNotification

enterpriseSpecific (6) / 2

1.3.6.1.4.1.44523.1.0.2

Agent, Target, or Wi-Fi Profile Incident

incidentEventNotification

enterpriseSpecific (6) / 3

1.3.6.1.4.1.44523.1.0.3

In SNMPv1 traps, NetBeez populates the agent_addr header with your licensed server IPv4 address if configured as a literal IPv4 address, or 0.0.0.0 when your server uses an FQDN.

Agent Device Alert VarBinds (beezAlertNotification)

Sent when Agents → Device Alerts is enabled and a Network Agent disconnects from the server or from its assigned Wi-Fi network (and again when it recovers):

Object Name

OID

Syntax

Description & Enumerations

beezAlertID

1.3.6.1.4.1.44523.1.1.1.1.1.1

OCTET STRING

UUID of the alert event being sent.

beezAlertType

1.3.6.1.4.1.44523.1.1.1.1.1.2

INTEGER

1 = beezReachabilityAlert (agent unreachable); 2 = beez80211 (Wi-Fi / BSSID disconnection).

beezSourceAlertID

1.3.6.1.4.1.44523.1.1.1.1.1.3

OCTET STRING

UUID of the opening alert event (matches beezAlertID on open; correlates cleared traps with raised ones).

beezAlertTimestamp

1.3.6.1.4.1.44523.1.1.1.1.1.4

DateAndTime

11-octet UTC timestamp when the alert event occurred.

beezName

1.3.6.1.4.1.44523.1.1.1.1.1.5

OCTET STRING

Display name of the Network Agent.

beezID

1.3.6.1.4.1.44523.1.1.1.1.1.6

OCTET STRING

UUID of the Network Agent.

beezAlertMessage

1.3.6.1.4.1.44523.1.1.1.1.1.7

OCTET STRING

Human-readable description of the raised or cleared device alert.

beezAlertSeverity

1.3.6.1.4.1.44523.1.1.1.1.1.8

INTEGER

1 = statusDown (alert opened); 6 = statusUp (alert cleared).

Test Alert VarBinds (testAlertNotification)

Sent when Targets → Alerts, Wi-Fi Profiles → Alerts, or Scheduled Tests → Alerts is enabled, as well as when you click Test on the SNMP settings page:

Object Name

OID

Syntax

Description & Enumerations

testAlertID

1.3.6.1.4.1.44523.1.1.2.1.1.1

OCTET STRING

UUID of the test alert event (00000000-0000-0000-0000-000000000000 on test verification traps).

testType

1.3.6.1.4.1.44523.1.1.2.1.1.2

INTEGER

1 = pingTest, 2 = dnsTest, 3 = httpTest, 4 = tracerouteTest, 5 = iperfTest, 7 = networkSpeedTest, 8 = voipTest, 9 = pathAnalysisTest, 10 = packetCaptureTest, 11 = customCommandTest.

testAlertSeverity

1.3.6.1.4.1.44523.1.1.2.1.1.3

INTEGER

1 = testAlertDown (critical/up-down), 4 = testAlertPerformance (warning/baseline/watermark), 6 = testAlertCleared (closed or test verification).

testSourceAlertID

1.3.6.1.4.1.44523.1.1.2.1.1.4

OCTET STRING

UUID of the opening alert event used to correlate close traps with the initial open trap.

testAlertTimestamp

1.3.6.1.4.1.44523.1.1.2.1.1.5

DateAndTime

11-octet UTC timestamp when the alert event occurred.

testBeezName

1.3.6.1.4.1.44523.1.1.2.1.1.6

OCTET STRING

Display name of the agent that triggered the test alert.

testBeezID

1.3.6.1.4.1.44523.1.1.2.1.1.7

OCTET STRING

UUID of the agent that triggered the test alert.

testTargetName

1.3.6.1.4.1.44523.1.1.2.1.1.8

OCTET STRING

Target resource/hostname, URL, or Scheduled Test destination.

testAlertMessage

1.3.6.1.4.1.44523.1.1.2.1.1.9

OCTET STRING

Alert message describing the condition (Test from the NetBeez SNMP integration on verification traps).

testTargetDisplayName

1.3.6.1.4.1.44523.1.1.2.1.1.10

OCTET STRING

Dashboard display name of the Target or Scheduled Test template.

Incident Event VarBinds (incidentEventNotification)

Sent when Incidents is enabled under Agents, Targets, or Wi-Fi Profiles and an Incident opens or clears:

Object Name

OID

Syntax

Description & Values

incidentEventID

1.3.6.1.4.1.44523.1.4.1.1.1.1

OCTET STRING

UUID of the specific opening or closing incident event.

incidentID

1.3.6.1.4.1.44523.1.4.1.1.1.2

OCTET STRING

UUID of the opening incident event (shared across both INCIDENT_OPEN and INCIDENT_CLEARED traps for correlation).

incidentEventMessage

1.3.6.1.4.1.44523.1.4.1.1.1.3

OCTET STRING

Message describing the incident state transition.

incidentEventTimestamp

1.3.6.1.4.1.44523.1.4.1.1.1.4

DateAndTime

11-octet UTC timestamp when the incident event occurred.

incidentSourceObjectType

1.3.6.1.4.1.44523.1.4.1.1.1.5

OCTET STRING

Source entity type: Agent, NbTarget, or WifiProfile.

incidentSourceObjectID

1.3.6.1.4.1.44523.1.4.1.1.1.6

OCTET STRING

UUID of the affected Agent, Target, or Wi-Fi Profile.

incidentSourceObjectName

1.3.6.1.4.1.44523.1.4.1.1.1.7

OCTET STRING

Display name of the affected Agent, Target, or Wi-Fi Profile.

incidentEventType

1.3.6.1.4.1.44523.1.4.1.1.1.8

OCTET STRING

INCIDENT_OPEN or INCIDENT_CLEARED.

UTC DateAndTime Wire Encoding

All three timestamp objects (beezAlertTimestamp, testAlertTimestamp, and incidentEventTimestamp) are transmitted in the standard 11-octet SNMPv2-TC::DateAndTime binary wire format normalized to UTC: 2-byte big-endian year, 1-byte month (1–12), day (1–31), hour (0–23), minute (0–59), second (0–59), and deci-seconds (0–9), followed by ASCII '+' (0x2B), 0 hours from UTC, and 0 minutes from UTC.