NetBeez NextGen (Version 20.0+) can forward real-time SNMPv1 or SNMPv2c traps to your network management system (NMS) whenever Network Agent device alerts, Target/Wi-Fi/Scheduled Test alerts, or correlated incidents open and close.
In this article:
Prerequisites
Administrator Access: Only NetBeez users with the Administrator role can access Settings → Integrations & Notifications.
Network Reachability: Allow outbound UDP traffic from your NetBeez server to your SNMP trap receiver on your chosen trap port (UDP
162by default; see Network Firewall Settings).NetBeez MIB Loaded on Your Receiver: Import
NETBEEZ-BEEZKEEPER-MIB(Version 4.0) into your SNMP trap receiver so incoming OIDs and varbinds decode properly (see SNMP Trap MIB & Payload Reference).
Configuring and Testing SNMP in NetBeez
In the left navigation sidebar, click Settings, expand Integrations & Notifications, and select SNMP (
/settings/integrations/snmp).In the SNMP Configuration card, complete the receiver settings:
SNMP Server (required): Enter the IPv4/IPv6 address, hostname, or FQDN of your SNMP trap receiver.
Trap Port: Enter the destination UDP port between
0and65535(defaults to162).Version: Select
v1(SNMPv1, default) orv2c(SNMPv2c).Read-Only Community: Enter the SNMP community string configured on your trap receiver (stored encrypted at rest in NetBeez).
If you have not yet imported the NetBeez MIB on your NMS, click Download NetBeez MIB above the action bar to open the NetBeez MIB repository.
Click Test to verify trap transmission before saving. NetBeez validates your current form inputs in memory and sends a test
testAlertNotificationtrap containingTest from the NetBeez SNMP integration. Because SNMP traps use connectionless UDP, confirm both that the success toast appears in NetBeez and that the test trap arrives on your SNMP trap receiver.Click Apply Changes to save your SNMP configuration.
Enabling SNMP Notification Subscriptions
Once your SNMP receiver settings are saved, choose which events emit SNMP traps in the Notifications card directly below SNMP Configuration:
Switch the toggle in the top-right header of the Notifications card from Disabled to Enabled.
Enable the desired event toggles across the four entity columns:
Agents:Device Alerts (Network Agent unreachable and Wi-Fi disconnection alerts) and Incidents.
Targets:Alerts (Ping, DNS, and HTTP test alerts) and Incidents.
Wi-Fi Profiles:Alerts and Incidents.
Scheduled Tests:Alerts (Iperf, Network Speed, VoIP, and Custom Command alerts).
Click Save at the bottom of the Notifications card.
For complete OID trees, VarBind tables, and severity/test-type enumerations, see SNMP Trap MIB & Payload Reference. For general notification behavior—including Maintenance Mode suppression—see Notification Contacts & Delivery Settings.